Alarm Time (For Alarm #2, if installed)
Alarm Mode (For Alarm #3, if installed)
Alarm Time (For Alarm #3, if installed)
Alarm Hysteresis
Low Calibration
High Calibration
Low Calibration (For Output #2 if installed)
High Calibration (For Output #2 if installed)
Low Calibration, Transmitter. (not used)
High Calibration, Transmitter. (not used)
Motor Timer
Wait (For program operation)
Hysteresis for Motor Control
Communication ID number
Baud Rate
SV Compensation
PV Compensation
Temperature Units
Soft Filter
Cascade
Action Mode (Heat or Cool)
Control Action
Frequency
Level 4 (Control Settings)
These settings should only be accessed by factory authorized personnel.
Quick Setup
For most applications you should be able to use the control directly out of the box. Simply hook the unit up
per the schematic at the back of the manual and perform the following steps:
The unit comes from the factory set to use a J thermocouple, input range of 0-792° F, upper set point
limit of 400° F, and a lower set point limit of 0° F (These values are displayed when the unit is turned on).
If you need to change these limits please see the instructions for changing level 3 parameters, otherwise
proceed to the next step below.
Press the ? key to select digits to change the SV (set point value). Press the ? or ? key to change the
digits up or down. Press the SET key to keep this setting.
Press the SET key again to access auto tuning. Press the ? key to change the value. Press the ? or
? to change the value to “yes”.
Press the SET key again to access the alarm value and change it if necessary.
Press the SET key again and allow the unit to auto tune. The auto tune light (AT) will remain on until the
unit cycles several times and locks in the process parameters. WARNING: THE AUTOTUNE
FEATURE ON THIS CONTROLLER MAY OVERSHOOT THE PROCESS TEMPERATURE. WHEN
AUTOTUNING TEMPERATURE SENSITIVE PROCESSES, THE TEMPERATURE MUST BE
MONITORED AT ALL TIMES DURING THE AUTOTUNING PROCESS. CONTACT THE GAUMER
CUSTOMER CARE DAPARTMENT WITH ANY QUESTIONS REGARDING THIS FEATURE.
For more detailed instructions or to change other parameters, please read on.
Changing Parameters
As mentioned earlier, there are 4 levels of menus. The menus are accessed as described in each menu